What are the common faults of forklift ignition system?

Apr 28, 2025

Leave a message

Forklifts are commonly used loading and unloading mechanical equipment. In order for forklifts to work properly, the gasoline engine ignition system must ensure that the mixture can be reliably ignited under various conditions. This article briefly introduces the composition of the commonly used battery ignition system and analyzes common faults.
Fault analysis and troubleshooting: Fault analysis and troubleshooting should be carried out from simple to complex. First, analyze and determine whether it is a low-voltage circuit fault, and then analyze and determine whether it is a high-voltage circuit fault.

(1) Turn on the ignition switch, the ammeter indicates "0", press the horn, and it does not sound. Cause of the fault: The low-voltage circuit is open, causing the battery current to be unable to output. Check whether the battery wiring is loose; whether the contact is good; whether the fuse and the battery and the ammeter are open; whether the ignition switch is in good contact.
(2) Turn on the ignition switch, the ammeter indicates "0", press the horn, and it sounds. Cause of the fault: The low-voltage circuit is open from the ignition switch to the distributor ground wire. Check whether there is a short circuit between the ignition switch and the primary winding of the ignition coil, the primary winding inside the ignition coil, the primary winding of the ignition coil and the distributor, and the distributor and the grounding wire. Use a screwdriver to ground the low-voltage terminal of the ignition coil to test the fire. If there is no spark, there is a short circuit between the ignition switch and the primary winding of the ignition coil, or the primary winding inside the ignition coil is short-circuited; if there is a spark, there is a short circuit between the primary winding of the ignition coil and the distributor, or the contacts inside the distributor cannot be closed, and the distributor grounding wire is short-circuited.
(3) Turn on the ignition switch, and the ammeter indication range is 3~5A and does not move. Cause of the fault: The low-voltage circuit is short-circuited between the primary winding of the ignition coil and the distributor. Check whether the primary winding of the ignition coil and the circuit between the primary winding of the ignition coil and the distributor are short-circuited; whether the contacts inside the distributor cannot be disconnected. At this time, although there is current flowing through the primary winding of the ignition coil, since the distributor contacts cannot be disconnected, this current is not pulse electricity and cannot generate an induced magnetic field to cause the secondary winding to generate pulse high voltage electricity.
(4) Turn on the ignition switch and the ammeter pointer swings to the maximum position. Cause of the fault: The low-voltage circuit is short-circuited between the ignition switch and the primary winding of the ignition coil. Disconnect the power supply and use a multimeter to measure the exact position of the short circuit between the ignition switch and the primary winding of the ignition coil in sections and eliminate it.