Analysis Of Common Faults in Electric Power System Of Electric Stacker

Sep 13, 2024

Leave a message

Electric stacker power system may present problems, mechanical equipment after long-term use is inevitable, electric stacker, electric truck and other electric storage equipment may encounter these problems, you can check in time according to the following reasons.

1, the charging voltage is too high fault phenomenon: electric stacker car engine operation process light bulb is easy to burn, battery electrolyte consumption too fast, use the DC voltage of the multimeter to measure the voltage value of the battery or generator at both ends, if higher than the standard value, the charging voltage is too high.

Fault cause: the operating voltage of the regulator is out of whack or faulty.

2, electric stacking truck charging voltage is too low fault phenomenon: during the engine operation, the charging indicator light shines or the ammeter swings around zero, using the DC voltage file of the multimeter to measure the voltage value of the battery or generator at both ends, such as lower than the standard value, the charging voltage is marked too low.

The cause of the fault: the regulator operating voltage is out of alignment or faulty, the transmission belt is too loose, the internal stator, rectifier, rotor and other parts of the generator are faulty.

3, no charging fault phenomenon: when the electric stacker engine is working normally, the charging indicator is on or the ammeter indicates a negative direction, indicating that the generator does not generate electricity and the battery does not charge.

The cause of the fault: generator fault, regulator fault or electrical line fault.